Materials Testing Automation and Robotic Specimen Loading

AMD Machines builds specimen loading, unloading and specimen-to-result tracking around the test frame, grips and software your laboratory runs or is specifying.

  • 30+years in business
  • 2,500+machines delivered
  • ISO 9001certified
  • 3 hoursreply time on weekdays
On this page
  1. What does a materials testing automation cell do?
  2. When does automating materials testing make sense for a research laboratory?
  3. How does a robot load a tensile test machine?
  4. Which signals does a specimen loading cell exchange with a materials test frame?
  5. What happens when a specimen breaks or a robotic loading attempt fails at the test frame?
  6. Which materials tests can be automated?
  7. Can you automate around an existing MTS test system?
  8. How are specimen identities linked to test results?
  9. Should a cobot or an industrial robot load a materials test frame?
  10. What does an automated tensile testing system cost, and what drives the price?
  11. What does a materials testing cell project include?
  12. How is specimen loading at a materials test frame different from production part testing and other robot cells?
  13. What should you send to get a quote for robotic specimen loading?
  14. Frequently asked questions about robotic specimen loading
  15. Key Features
  16. Applications
  17. Benefits
  18. Which inquiry route fits your request?

Materials testing automation is equipment that loads, aligns and unloads specimens at a mechanical test frame and links each result to its specimen ID; AMD Machines builds it around the laboratory's frame, which keeps doing the testing and measurement.

Materials testing automation serves university research groups, national laboratories, shared research facilities and industrial materials R&D teams whose staff load specimens into a universal testing machine one at a time, clear fractures and match results to specimen numbers by hand. AMD Machines reviews the installed or specified frame, grips, extensometer, controller and software, then defines what the automation does and what stays with the test system. A project can start from the frame's make and model, specimen drawings and an approximate batch size.

AMD Machines, founded in 1996 and ISO 9001 certified, designs and builds custom automation and robotic systems: 30+ years in business, 2,500+ machines delivered across North America. Materials testing is one of the workflows in AMD Machines' research laboratory automation section.

Materials testing automation from AMD Machines at a glance:

Topic AMD Machines answer
What AMD Machines builds and integrates Specimen magazines and trays, the robot and its end-of-arm tooling, ID reading, optional cross-section measurement, cell controls, safeguarding and the link from each result to its specimen ID
What stays with the test system and the laboratory Test method, test control, force and strain measurement, data acquisition, calibration and service
Which test frames The frame your laboratory runs or is specifying, MTS or another make, once an interface review confirms what a cell can work with
Most direct fit Room-temperature tension (ASTM E8/E8M) and compression (ASTM E9) testing of metals, on frames configured for automated loading
Separate configuration reviews Fatigue testing (ASTM E466, ASTM E606/E606M) and elevated-temperature testing (ASTM E21 for tension, ASTM E209 for compression)
Price No standard price; each cell is priced from its reviewed scope
Lead time for a materials testing cell Set at proposal; AMD Machines' published lead times across all machine types are as little as 6 weeks for simple machines and 24–26 weeks for complex systems
What AMD Machines returns A feasibility assessment and budgetary quote, at no cost

What does a materials testing automation cell do?

A materials testing automation cell from AMD Machines combines up to seven functions: specimen presentation, identification, dimension measurement, robotic loading and alignment, equipment-status coordination, unloading and sorting, and specimen-to-result association. Which of them a project needs depends on the specimens, the test frame and how the laboratory runs its batches.

  • Specimen presentation. A magazine, tray or carrier fixes each specimen's position and orientation, and presence sensors or a camera confirm what was loaded.
  • Identification. A barcode or Data Matrix reader confirms the specimen ID, or the tray position stands in for it when a specimen cannot be marked.
  • Dimension measurement, when the method needs it. Stress values are calculated from the measured cross-section (thickness and width of a flat coupon, diameter of a round specimen), so a measuring station before the test can be part of the scope.
  • Robotic loading and alignment. The robot places the specimen in the grips, on compression platens or in a fixture at the position the method requires, and holds it while the grips close.
  • Equipment-status coordination. The cell and the test system exchange states such as ready, grips closed, test complete and fault.
  • Unloading and sorting. After the test, the robot removes the specimen, or both halves of a broken one, to an identified position.
  • Specimen-to-result association. The cell joins the result data the test system makes available to the specimen ID confirmed before the test.

Which materials testing tasks move to the automation, and which stay with the test frame?

In a materials testing cell from AMD Machines, the automation takes over specimen handling, identification, cell controls and robot safeguarding, while the test system and the laboratory keep the test method, force and strain measurement, calibration and service.

Function AMD Machines automation scope Stays with the test system and the laboratory
Specimens and batches Magazines, trays and carriers; presence checks; batch tracking Specimen preparation, the test plan and batch definition
Identification Barcode or Data Matrix reading, tray-position tracking, handling of unreadable codes The specimen numbering scheme
Loading and removal Robot, end-of-arm tooling, seating checks, broken-half removal Grip hardware, jaw faces and load-train alignment
Grip actuation Requesting grip close and open through reviewed signals Gripping pressure and grip control settings
Testing and measurement Waiting on the test-system states the interface review confirms, such as ready, running and complete Test method, test control, force and strain measurement, data acquisition
Extensometry Reach paths and clearance for automatic or non-contact extensometers Extensometer selection, attachment and verification
Calibration and service Not in scope; any measuring station the cell adds is identified for the owner's calibration program Force verification, extensometer verification and equipment service
Results Linking available result data to specimen IDs and exporting it in an agreed format Analysis, reports and the laboratory's own records system
Safety Risk assessment, safeguarding and safety circuits for the robot cell Frame shields and the frame's own safety functions

When does automating materials testing make sense for a research laboratory?

Automating materials testing makes sense when specimen handling, not the test itself, limits how many specimens a laboratory can test: batches of similar specimens, short tests and staff hours spent waiting at the frame. One-off tests and method development usually stay manual, and long tests gain less from a robot unless it serves a second frame or carries a batch overnight.

  • Test duration against handling time. A robot keeps the frame busy when tests are short compared with loading, measuring and clearing. When a person can prepare the next specimen during a test, robotic loading adds less, and identification and data association may be the better first scope.
  • Repeat specimens. Batches of one geometry and one method, typical of high-throughput materials testing programs, automate well. Small batches with frequent shape changes mean more gripper and jaw-face changeovers.
  • Unattended hours. A full specimen magazine lets a batch continue into the evening or overnight, provided the exception responses are defined and the risk assessment allows unattended running.

To weigh the staff hours a cell saves against its cost, our robot ROI calculator and payback model sets out the arithmetic.

How does a robot load a tensile test machine?

A robot loads a tensile test machine by placing the specimen between open grips at the position the method requires, holding it while actuated grips close and releasing it without pulling it out of line. Whether a given frame allows that depends on four physical points and on the signals the installed controller can exchange, which AMD Machines reviews before a cell is designed:

Point reviewed Ready for robotic loading Needs a test-system change, an operator step or a separate review
Grip actuation Pneumatic or hydraulic grips that close on a command, or motor-driven grips whose close command the interface review confirms Manual wedge grips or hand-tightened screw grips
Specimen shapes Repeat geometries, batched by shape, with jaw faces to suit Frequent shape changes, or threaded and button-head ends that seat in holders
Extensometer An automatic contact extensometer, a non-contact extensometer, or a method that needs none A clip-on extensometer attached by hand
Enclosure access An opening in the shields or doors the robot can reach through A shield door that must close for every test, or a chamber or furnace around the specimen
Controller signals Documented states such as ready, grips closed, test complete and fault States the controller cannot report, covered by cell sensors or an operator step

How is grip actuation coordinated with the test machine?

Grip actuation is coordinated by a close command to actuated grips while the robot holds the specimen in position. Which device sends that command (the test system's controller, a separate grip controller or the cell) is settled in the interface review, because gripping pressure is part of the test setup and stays under the laboratory's control.

AMD Machines checks grip actuation first, because it decides whether a robot can load the frame without a person closing the grips. Pneumatic and hydraulic grips, including hydraulic wedge grips, apply gripping force on a command; with manual wedge or screw grips, the options are actuated grips added by the laboratory or keeping grip closing as an operator step.

As in careful manual loading, the aim is to grip the specimen without bending, pre-stressing or slippage. The AMD Machines review also checks whether the test system can hold near-zero force while the grips close, so closing them does not load the specimen or the robot before the test starts.

Can a robot load both flat coupons and round specimens?

Yes, a robot can load both flat coupons and round specimens when the frame's grips and the robot's gripper are set up for both shapes. Flat (dog-bone) coupons cut from sheet, strip or plate and round machined specimens usually need different jaw faces in the grips and different fingers on the gripper. Round specimens with threaded or button-head ends seat in threaded or shouldered holders rather than wedge jaws, which changes the loading motion and is reviewed separately.

Gripper fingers can be designed to hold both shapes, or a tool changer can swap fingers between batches. A jaw-face change on the frame is usually an operator step, so batches are often grouped by specimen shape. Drawings of every specimen geometry in the test plan let AMD Machines check all of this before the design is fixed.

How are test specimens gripped and sorted by the robot?

A specimen loading robot from AMD Machines grips test specimens with end-of-arm tooling (EOAT) that AMD Machines designs in-house, with fingers shaped for each specimen geometry and compliance where the specimen must settle into the grips. After the test, automated specimen sorting can send each tested specimen to a position by test group, condition or retention plan. Cell architecture, including end-of-arm tooling and cell controls, is described under robotic cells.

Can the extensometer be attached automatically during robotic loading?

An extensometer can be attached automatically only if it is designed for it: sensor-arm extensometers come in versions that attach automatically, non-contact video or laser extensometers need no attachment, and clip-on extensometers are designed to be attached to the specimen by hand.

Because the extensometer affects the result, AMD Machines' part is limited to reach, clearance and timing around the device the laboratory chooses. A non-contact extensometer also needs a clear line of sight, so the robot and its gripper stay out of its field of view while the test runs.

How does a loading robot reach into a test frame's enclosure?

A loading robot reaches the test space of a materials test frame through an opening in the frame's shields or doors, so AMD Machines reviews those openings, how the doors are opened and interlocked, any environmental chamber or furnace around the specimen, and the clearance to the load cell, grips and extensometer during loading.

The AMD Machines review also settles whether a shield door can stay open through a batch, with the cell's safeguarding around the opening, or must close for each test. A powered, interlocked door on the frame is a change to the test system, which the laboratory specifies with its test-system supplier.

Which signals does a specimen loading cell exchange with a materials test frame?

A specimen loading cell and a materials test frame exchange a small set of equipment states, and an AMD Machines interface review confirms before design starts which of them the installed controller and software can report and which commands they accept. The cell typically needs to know when:

  • the frame is ready for a specimen (crosshead or actuator at the loading position, test space clear, no active fault);
  • the grips are open or closed, and which device commands them;
  • a test is running, has completed or was stopped;
  • the frame is in a safe state for the robot to enter the test space;
  • a fault or alarm should pause the batch.

The states travel over whatever the installed controller documents, such as discrete digital inputs and outputs. Where it cannot report a state electronically, the cell can confirm it with its own sensors, or that step stays with an operator.

A status signal is not by itself a safety function. Whether the robot may enter the test space while the crosshead or actuator is powered, and which safety-rated devices or frame interlock inputs that requires, is decided in the risk assessment.

What happens when a specimen breaks or a robotic loading attempt fails at the test frame?

When a specimen breaks or a loading attempt fails, a materials testing cell from AMD Machines follows a response defined in its scope: it stops before the test if loading is uncertain, removes both halves of a broken specimen to that specimen's position, and sends anything unresolved to an exception position for a person to review.

Exception Typical response defined in the scope
Specimen missing from the gripper Stop before the test and record the event against the specimen ID
Specimen not seated, out of alignment, or grips not confirmed closed Stop before the test starts and return the specimen to its position or an exception tray
Unreadable ID code Send the specimen to an exception position, not into the grips
Specimen breaks Remove both halves to the specimen's identified position and check that the grips and test space are clear before the next load
Specimen slips in the grips, or the test system stops the test Move the specimen to an exception position with its record
Test-system fault or alarm Pause the batch and flag the current specimen for a person
Interlocked guard or door opened The safeguarding stops the robot, and restart follows the steps defined in the scope
Emergency stop, power loss or operator stop Hold the batch until an operator confirms the test space and the specimen states

Whether to retest a specimen that slipped, or one whose test the test system stopped, is the laboratory's decision, not the cell's. Agreed acceptance testing exercises these responses: at the factory, AMD Machines runs validated sample specimens through the sequence and tests every failure mode we can simulate, and the responses that need the live frame and its grips are proven at site acceptance.

How are broken specimen halves removed and kept with the right specimen ID?

A materials testing cell from AMD Machines can be scoped to keep broken specimen halves with the right specimen ID by placing both halves in the tray position assigned to that ID, and to hold the next load and flag the specimen for a person whenever it cannot confirm that both halves were removed and the test space is clear. A tensile fracture leaves two halves, sometimes small fragments, that can end up in different places in the test space. Where fracture surfaces will be examined later, the halves are placed so their fracture surfaces are not touched by the gripper, the tray or each other.

How does a materials testing cell recover from an interrupted batch?

A materials testing cell from AMD Machines recovers from an emergency stop, power loss, fault or operator stop by tracking each specimen's state (for example untested, loaded, tested, removed or exception), so an operator can confirm the test space and the specimen states before the batch resumes. Untested specimens can return to their original positions, the scope can require that nothing is retested or discarded without a person's confirmation, and it sets how a stop is reported when nobody is at the cell: on the HMI, by a stack light and, where agreed, by an alert message.

Which materials tests can be automated?

Automated tensile testing and automated compression testing of metals at room temperature, on frames configured for automated loading, are the most direct fit for robotic specimen loading: the specimen geometry is defined, the grips or platens can be actuated or reached, and the test ends in a clear state the cell can wait for. AMD Machines reviews fatigue testing automation and elevated-temperature testing as separate configurations, not options added to a tension cell.

Test type Common US reference What the automation review adds
Tension (tensile) testing of metals at room temperature ASTM E8/E8M Grip actuation, jaw faces for flat and round specimens, extensometer type, broken-half removal
Compression of metals at room temperature ASTM E9 Platen or fixture placement, centering, specimen recovery after the test
Force-controlled constant-amplitude axial fatigue ASTM E466 (a practice) Fatigue-rated grips, long test durations, specimens that do not fail
Strain-controlled fatigue ASTM E606/E606M Extensometer attachment for cyclic straining, alignment, long test durations
Tension of metals at elevated temperature ASTM E21 Furnace or chamber access, specimen heating, hot specimen removal, extensometry suited to temperature
Compression of metals at elevated temperature ASTM E209 (a practice) As for elevated-temperature tension, with compression fixtures

The automation does not change the test method, and conformity to a standard stays with the laboratory. A robot can load specimens through the opening of a furnace or environmental chamber on the frame only where that opening, the grips and the extensometry allow it.

AMD Machines reviews flexure, impact and tests of non-metallic materials, such as tensile tests of plastics (ASTM D638) or polymer matrix composites (ASTM D3039/D3039M), case by case. Laboratories that work to ISO methods review the same points; ISO 6892-1, for example, covers room-temperature tensile testing of metals.

Can you automate around an existing MTS test system?

Yes, where the installed equipment allows it: AMD Machines can automate specimen loading around an existing MTS test system once a review of the installed frame, grips, extensometer, controller and software confirms what a cell can work with. The scope is defined around that installed configuration, the same way as for a test frame of any other make, and nothing is assumed compatible before the review.

Robotic specimen loading at a test frame is an established application: MTS states publicly that it has integrated third-party automation systems, including a robotic arm specimen loading system. That public material creates no relationship between MTS and AMD Machines. AMD Machines is not an MTS partner or authorized service provider, and nothing on this page implies MTS approval.

An MTS Custom Test Template Development Service brochure describes templates with external dependencies that can include control of a robot or an X-Y positioning table. Whether a project needs test-software work of that kind is settled during the AMD Machines interface review, and that work may involve the laboratory's test-system supplier.

What information does AMD Machines need about an MTS frame, controller and software?

To scope automation around an MTS test system, AMD Machines needs the frame type and model, grip actuation, extensometer type, controller inputs and outputs, software package and version, and the enclosure and safety devices. The same list applies to a frame of any other make.

Item What AMD Machines asks for Why it matters
Frame Type (electromechanical or servohydraulic), model, test space, crosshead or actuator travel, free space around the frame Sets robot reach, approach paths and where the cell can stand
Grips Make, model and actuation (manual, pneumatic, hydraulic or motor-driven), jaw faces in use, how gripping pressure is set and commanded Decides whether a robot can load without a grip change
Extensometer Type (clip-on, automatic contact or non-contact) and how it is attached and removed Clip-on extensometers are designed to be attached by hand
Controller Model, available inputs and outputs, how test start, stop and completion are signaled, interlock inputs Defines what the cell can know and request
Software Package and version (for example, MTS TestSuite), test methods in use, how specimen IDs are entered and results exported Defines how results reach the specimen record
Enclosure and safety Shields, doors, interlocks, any chamber or furnace Defines access to the test space and how the frame's safety functions relate to the cell's
Service and calibration Current service and calibration arrangements Shows who re-verifies the frame if an adapter is added to the load train

Controller and software manuals, wiring documentation for any auxiliary inputs and outputs, photos of the frame, grips and enclosure, and screenshots of a test method setup help start the review. AMD Machines does not assume a software programming interface, a remote-start function or a handshake common to every MTS controller; what the installed version offers is confirmed, with the laboratory's test-system supplier where needed.

What stays with the MTS system and its supplier?

The MTS system keeps performing its specified testing and measurement functions: test control, force and strain measurement, data acquisition and the analysis in its software. Changes to the test system itself, such as actuated grips, a different extensometer, added input and output options or frame-side safety devices, are specified by the owner with its test-system or accessory supplier.

AMD Machines does not service, repair or calibrate MTS equipment. Calibration of the test system stays with the owner's calibration program, which covers force verification of the frame (ASTM E4) and verification of extensometers (ASTM E83) by the laboratory or a calibration provider, such as one accredited to ISO/IEC 17025; our calibration management guide explains how to build the instrument inventory behind that program.

Can AMD Machines design custom fixtures for MTS test systems?

Yes, as part of an automation scope built around the laboratory's installed frame: AMD Machines designs specimen nests, magazines, robot-friendly fixtures and adapters for an MTS frame in the same review as the cell. Anything that sits in the load train affects the test, so its design is agreed with the laboratory before it is made. Fixtures, holders and adapters on their own, without a robot cell, are covered on our custom laboratory parts and fixtures page.

How are specimen identities linked to test results?

In a materials testing cell from AMD Machines, the specimen ID is read before the test and joined to the result data the test software makes available, so the ID stays with the specimen after a fracture, a stopped batch or a decision to retest. Identity can come from:

  • A barcode or 2D Data Matrix code marked on the specimen outside the gauge section, or on its tag or carrier;
  • An engraved or printed number read by a camera;
  • The specimen's position in an identified tray, when a specimen is too small to mark or a mark could affect the test.

The rule AMD Machines uses on its production test systems carries over: barcode scan, RFID read, or serial number entry before every test. No scan, no test. Where the tray position stands in for the ID, the cell confirms the position and the specimen's presence before loading, so the same rule holds: no confirmed identity, no test.

An AMD Machines cell can record the specimen ID, its tray position and its handling events (for example loaded, tested, removed or exception) and join them to the exported values or result files. Where the test software can accept the specimen ID before each test, the ID travels into the result. Where it cannot, the cell can match each result to the specimen it loaded, one test at a time, so a missing or extra result stops the matching for a person to resolve instead of shifting every later record.

Records can be passed on through OPC UA, MQTT or direct database writes, or as files in an agreed format where a network connection is not allowed; the network connection and any IT or cybersecurity approval your institution requires are agreed in the scope. Linking available instrument data to specimen identity is a defined integration scope: AMD Machines does not supply a LIMS, an electronic laboratory notebook or the analysis of results, and the cell hands its records to the system the laboratory already uses.

Our marking and traceability solutions cover mark verification and traceability, part marking and traceability systems describes the marking station itself, and camera-based presence checks and code reading are covered under machine vision.

Should a cobot or an industrial robot load a materials test frame?

Either a cobot or an industrial robot can load a materials test frame; the risk assessment decides, because the frame is a hazard in its own right: a moving crosshead or actuator, gripping force, and the energy released when a specimen fractures. A cobot lets staff work near the cell for some tasks, but it does not make the test space safe to reach into during a test, so that space is safeguarded either way.

AMD Machines, a Universal Robots Certified Integrator, integrates both cobots and industrial robots; our cobot payback period guide covers the economics of the choice.

How is robotic specimen loading safeguarded at a test frame?

Robotic specimen loading is safeguarded on the basis of a risk assessment that covers the robot and the test frame together: the frame keeps its own shields and safety functions, and AMD Machines adds the safeguarding, safety circuits and interlocks the assessment calls for, with the safety documentation package it delivers with every system.

The US rules and standards that apply to a laboratory robot, including ANSI/A3 R15.06-2025 and state-plan and DOE coverage, are summarized under how a laboratory robot is made safe around researchers; our robot safety standards guide explains risk assessment and collaborative operation in more detail.

What does an automated tensile testing system cost, and what drives the price?

AMD Machines has no standard price for an automated tensile testing system: the test frame, grips and extensometer come from the laboratory and its test-system supplier, and AMD Machines prices the automation around them from its reviewed scope, starting with a feasibility assessment and budgetary quote, at no cost. Eight scope decisions drive the price of an AMD Machines materials testing cell:

Scope decision What it adds to the cell
Test frames served Robot reach, floor space, an interface review and inputs and outputs for each frame
Specimen geometries Nest positions for each shape, gripper fingers that hold every shape in the test plan or a tool changer, and possibly jaw-face changes
Unattended run length Magazine capacity, and exception responses that work without a person
Cross-section measurement A measuring station to design, prove at acceptance and identify for the owner's calibration program
Grip or extensometer changes Signals and clearances for new grips or a new extensometer, which the laboratory orders from its own suppliers on their schedules
Identification and data integration Code reading, result matching, the export format or network connection, and any IT approval
Exception handling The failure modes the cell must detect, record and recover from
Safeguarding The guarding, safety circuits and interlocks the risk assessment calls for

Our automation pricing guide gives AMD Machines' published budgetary ranges by system type; those ranges are not a price for a materials testing cell. For a grant or capital request, AMD Machines can prepare the budgetary quote once the frame, specimens and batch needs are known.

How long does AMD Machines take to build a materials testing cell?

AMD Machines sets the lead time for a materials testing cell at proposal. For machines in general, AMD Machines delivers simple machines in as little as 6 weeks and complex systems in 24–26 weeks, vs. 40–42 weeks typical for overseas builders.

Our custom automation lead times guide explains what moves a schedule.

What does a materials testing cell project include?

A materials testing cell project from AMD Machines typically includes the end-of-arm tooling, magazines, trays and nests, the cell controls with the reviewed test-system interface and agreed data export, safety engineering, and factory and site acceptance tests against agreed criteria; the test system's service and calibration stay with its owner and providers.

Installation, documentation, training, spare parts, the shared Smartsheet project plan and maintenance and support follow the standard AMD Machines package described under what AMD Machines delivers on a laboratory automation project.

How is a materials testing cell tested before and after delivery?

A materials testing cell is proven in two stages: a factory acceptance test (FAT) at AMD Machines' facility before shipment, usually without your test frame because it stays in service in your laboratory, and a site acceptance test (SAT) in your laboratory with the frame. The frame is out of service mainly during installation and the SAT, a period set in the project plan together with any grip or extensometer change made at the same time.

Stage Where it runs What it proves
Factory acceptance test (FAT), which you can attend AMD Machines' facility in Querétaro, Mexico, before shipment, against a simulated test system Magazine and tray handling, ID reading, the robot's gripper on every specimen geometry using validated sample specimens you supply, the signal exchange and the exception paths
Site acceptance test (SAT) Your laboratory, with the live frame and controller Seating in the installed grips, broken-half removal, extensometer and enclosure clearance, the signal exchange with the live controller, and the owner's alignment re-check where the load train changed

For the general difference, see how factory testing and final onsite integration differ and our guide to how custom automation projects move from concept to commissioning.

How is specimen loading at a materials test frame different from production part testing and other robot cells?

Specimen loading at a test frame serves research and materials laboratories: AMD Machines' materials testing automation moves specimens through a mechanical test frame and keeps each result with its specimen ID. Production part testing, CNC machine tending, furnace work and vacuum work each have their own AMD Machines page:

What should you send to get a quote for robotic specimen loading?

To get a quote for robotic specimen loading, send AMD Machines the test frame's make and model, drawings of each specimen geometry and an approximate batch size. That is enough to start a feasibility assessment and budgetary quote, at no cost; for a system or integration inquiry, these details let AMD Machines engineers judge feasibility and scope:

Item What to include
Process to automate Test methods, the steps that are manual today, and where the handling problem is (waiting at the frame, loading consistency, broken-specimen cleanup, record keeping)
Equipment make and model Frame, controller, software and version, grips and their actuation, extensometer, and any chamber or furnace
Specimens Geometries with drawings, materials, size and mass range, surface condition, and how specimens are identified today
Sample specimens A few of each geometry for gripper design; the validated sample specimens for the factory acceptance test are planned with the scope
Batch and throughput Approximate specimens per batch and per week, and how long the cell should run without attention
Data Which results must be linked to each specimen, and where records go today
Site and timing Floor space and utilities around the frame, photos of the frame and enclosure, and your target timing

AMD Machines is currently not compliant with the International Traffic in Arms Regulations (ITAR), and no email address, form or file upload on this website is approved for ITAR-controlled or other export-controlled information. If a project may be ITAR sensitive, tell AMD Machines only that, and send nothing until AMD Machines confirms in writing how it is to be handled, as the ITAR notice explains.

Frequently asked questions about robotic specimen loading

Can you automate our existing tensile testing machine, or do we have to buy a new automated system?

Yes, AMD Machines can automate an existing tensile testing machine of any make instead of replacing it with a new automated system, when a review shows that its grips, extensometer, test-space access and controller signals allow it. When robotic loading is not practical yet, for example with manual grips and a clip-on extensometer, a first scope can still cover specimen identification, dimension measurement and specimen-to-result association, with robotic loading added after a grip or extensometer change.

Can one robot serve two test frames?

Yes, one robot can serve two test frames when both test spaces are within its reach and the risk assessment allows it to work at one frame while the other is testing or in use by hand. AMD Machines reviews reach, floor space and inputs and outputs for each frame; a second frame added later needs them reserved in the first scope. A shared robot adds the most on long tests, unloading and reloading one frame while the other runs. The cell tracks each frame's status and specimen separately, with the frame ID in every record.

When should automation be considered for a new test frame?

Automation should be considered before the frame order is placed. Actuated grips, an extensometer that does not need to be attached by hand, the controller's input and output options and access through the enclosure are easier to specify with a new frame than to add later. The laboratory orders them from its test-system supplier, and AMD Machines reviews the proposed configuration for robot access, signals and clearance before the order is fixed. The same points are in our frame, controller and software checklist.

Will robotic specimen loading change our test results?

Robotic specimen loading is not meant to change test results: the test method and force and strain measurement stay with the test system, and the agreed acceptance tests check everything the cell adds that touches the test, such as seating, gripping or a load-train adapter, against the laboratory's manual procedure. An AMD Machines cell is typically scoped to stop before the test when seating, alignment or grip closure is not confirmed. Where the load train changed, the owner re-checks frame and specimen alignment (ASTM E1012) and force verification (ASTM E4).

Can staff still run manual tests on the test frame after automation is added?

Yes, a test frame with robotic specimen loading from AMD Machines stays available for one-off and method-development tests through a manual mode defined in the scope: the robot parks clear of the test space, staff test by hand, and the operator confirms the test space and specimen positions before handing the frame back to the cell. Staff refill magazines from outside the safeguarded area, and operator training covers these handovers.

Is robotic loading worth it for fatigue testing?

Robotic loading helps a fatigue test program mainly by starting the next specimen while nobody is in the laboratory, after a separate configuration review by AMD Machines. Fatigue tests usually run in grips rated for cyclic loading and last far longer than tension tests, so loading speed matters less than starting runs overnight or over a weekend, which the risk assessment must allow. The review also covers specimens that do not fail.

Key Features

  • Robotic specimen loading and unloading
  • Specimen magazines, trays and carriers
  • Grip actuation coordination
  • Seating and alignment checks
  • Optional cross-section measurement before the test
  • Barcode and Data Matrix specimen identification
  • Broken-specimen removal and sorting
  • Specimen-to-result data association
  • Interrupted-batch recovery and restart

Applications

Tensile Testing

Robotic loading of flat coupons and round specimens into actuated grips on frames configured for room-temperature tension testing of metals, such as ASTM E8/E8M.

Compression Testing

Specimen placement on platens or in compression fixtures for room-temperature methods such as ASTM E9, with placement and recovery defined in the scope.

Fatigue and Elevated-Temperature Testing

Reviewed as separate configurations, because fatigue-rated grips, long test durations, specimen heating and temperature-suited extensometry change the cell.

Specimen Sorting and Retention

Post-test removal of the specimen, or both halves of a broken one, to identified trays so every fracture surface stays with its specimen record.

Benefits

Repeatable Handling

Every specimen in a batch is presented, seated and released by the same programmed motion instead of by hand.

Staff Time Back

Staff fill a magazine and return to their analysis instead of waiting at the frame to load each specimen and clear each fracture.

Identity Kept

Each result, broken half and retained specimen stays linked to the ID confirmed before the test, including after a stopped batch.

Measurement Stays With the Test System

The frame, controller and software keep their specified testing and measurement functions. Any grip, extensometer or input and output change is the laboratory's decision with its suppliers.

Which inquiry route fits your request?

Use the first route for automation or integration around your instruments, and the second for fixtures, components and spare parts. Both lead to the same contact form, and the details listed help AMD Machines engineers understand the request and ask the right follow-up questions. Please do not send ITAR-controlled or other export-controlled information. See our ITAR notice.

Laboratory automation or instrument integration

Choose this route for robotic specimen handling, furnace and quench transfer, vacuum-system integration, or coordinating instruments you already own.

  • The process or instrument you want to automate
  • Equipment make and model, with its controller and software
  • Specimen description: material, shape and size range
  • How specimens are handled today, and what needs to change
  • Approximate batch size or throughput
  • Target timing, such as a funding or installation date
Discuss a laboratory automation project

Custom part, fixture or spare review

Choose this route for sample holders, instrument adapters, fixtures, carriers, replacement parts and repeat spare kits. Alumina, MACOR, tungsten and molybdenum requests are reviewed part by part before AMD Machines confirms whether it can quote them.

  • Drawing with its revision, or an approved reference sample
  • Exact material grade or specification, not only the material name
  • Quantity, and whether you expect repeat orders
  • Critical dimensions and mating features
  • Operating environment: temperature, atmosphere or vacuum, and loads
  • The instrument or assembly the part fits
Request a custom part review

Ready to discuss your Materials Testing Automation project?

Our engineering team has 30+ years of experience designing custom automation solutions.